Single components for refrigeration, heating and ventilation circuits

The interval hangs on the charge, not on your diary, so a failed component is no repair — it is a deadline with a parts list on it. On shukchok length, width, depth and connection thread stand at the position, and the record is still in your account five years later.

Dampf-Heizregister 1/2 Zoll mit zwei senkrecht stehenden Messing-Anschlussstutzen und Kupferrohr-Aluminiumlamellen-Wärmetauscher

Your plant file

The expensive word in this trade is assembly

The condenser is fouled or corroded on the air side, and the rest of the unit runs. You want to change the one component — and you are quoted the whole assembly, because the single part appears in nobody’s price list.

The second annoyance arrives later. Art. 7 of the F-gas Regulation requires records per unit of equipment for at least five years; in year four you are hunting for a document that was filed by month rather than by plant.

Both are the other way round here. Evaporator, evaporator coil, condenser coil and refrigerant recovery tank are separate positions with their dimensions stated, and your purchase order number files the purchase against the plant instead of against the calendar week.

  • Dimensions and connection size at every position, no data-sheet download needed
  • Purchase order number and cost centre run through to the invoice
  • Invoice available as a PDF in the customer account, and it stays there

What the interval hangs on

The charge decides, not the size of the plant

Leak check below 50 t CO₂ equivalent
12 months
Art. 5(6)(a) Regulation (EU) 2024/573; 24 months with a leak detection system installed
From 50 to below 500 t CO₂ equivalent
6 months
Art. 5(6)(b); 12 months with a leak detection system
From 500 t CO₂ equivalent
3 months
Art. 5(6)(c); 6 months with a leak detection system, which is itself mandatory from this threshold (Art. 6)
Minimum retention of the equipment records
5 years
Art. 7(2) of the same regulation — including the company that did the work and its certificate number

Four figures per component

Heat-transfer components as single positions

Dimensions and connection size are the selection criteria. Everything below is individually orderable.

Taken from the article descriptions, 8 August 2026. Aluminium fins are joined to copper tubes by mechanical expansion; the article description names water, glycol mixture, antifreeze, thermal oil and steam as heat transfer media. That pairing is also where the limit sits once the outside air turns aggressive.
ComponentDimensionsConnectionNote
Evaporator B-440475 × 355 × 158 mm1/2" maleCopper / aluminium
Evaporator coilHeat transfer area 18.7 m²1/2"Lists compatible series on the article
Condenser coil F13142 × 355 mm1/2"Finned, nickel-plated tube coil
Heating register Smart370 × 185 × 65 mm1/2" maleCopper / aluminium
Steam heating register380 × 300 × 69 mm1/2" maleCopper / aluminium
Refrigerant recovery tankA pressure vessel, not a container
Screw-in heater6 kWStainless 1.4404
Druckschalter PR20 aus Edelstahl mit grünem Dichtring am frontbündigen Prozessanschluss, Typenschild mit CE-Kennzeichnung und M12-Rundsteckverbinder am Sensorkopf

What one ordering process changes

Flush or not — the difference is in the table, not in a reply

shukchok is an open marketplace for industrial goods, and it lists two pressure switches side by side — one standard and one flush-diaphragm, both with 1.4301 wetted parts. That is not a styling variant: where media bake on or the line is cleaned in place, a diaphragm at the bottom of a blind bore reads the deposit instead of the process.

The price difference is small, the application difference is not — and it stands in the specification table rather than in the answer to an enquiry. The same holds for the vents: one explicitly for steam, two for water circuits.

You can compare all of that without a login, in euro and net. The account is needed only when cost centre and company data should be stored for good — or when you pull the invoice for the same plant out of the history for the fourth time.

  • PT100 screw-in probe 1/4", PT100 sensor and contact thermometer in the catalogue
  • Several manufacturers, one basket and one payment at checkout
  • A completed order goes back into the basket in one step

Two ways in

Measure the component, not the assembly

Length, width, depth and connection thread stand at every position, and the invoice stays findable in the account. And if you make or distribute refrigeration equipment: shelf space here costs you no fee.

The webshop for the industry